INT 209-073 / K09073 Correlation report Tsukuba VLBI Correlator [Geographical Survey Institute, Japan] Observed: Mar 14, 2009 doy073/07:30-073/08:29 Correlated: Mar 16, 2009 Exported: done Station Comments ---------------- TSUKUB32(T-Ts): There were errors in the time of the header data of S1-S4ch in scan 073/07:35,07:38,08:01,08:06, 08:09,08:16 and 08:18. These scans are not included in this primary solution. Recorded on K5(VSSP32). WETTZELL(V-Wz): The value of "fmout-gps" has changed from -13sec to -20usec. The value of rate was large for -14E-12 sec/sec. (This value was calculated from the value of the log file.) Recorded on Mark5. It is maybe because the rate value of WETTZELL is large as the cause that the error value of this dUT1 grew. - comment: Intensive eVLBI session with TSUKUB32 and WETTZELL. Recorded Data on Mark5 at WETTZELL were transferred to Tsukuba Correlator via network. Converting Mark5 data into K5 form at Tsukuba Correlator. Processed on K5 correlation system. PF=1.70 Station Clocks -------------- Clocks: GSI Station fmout-gps used rate Comments [usec] [usec] [sec/sec] Ts 0.520 0.520 -0.077E-12 Reference Wz -20.310 -21.453 -3.642E-12 Date: 2009/03/14 - comment: correlation package:apri_calc(NICT,Ver.2008-02-19). cor(NICT,Ver.2008-09-30). komb(NICT,Ver.2008-02-19). Statistics ---------- PROCESS SUMMARY BY BASELINE/FREQUENCY Base 0 1 2 3 4 5 6 7 8 9 D G N - Tot TV X 0 0 0 3 0 7 1 4 0 13 0 0 7 0 35 TV S 1 0 0 0 0 0 1 3 7 16 0 0 7 0 35 Column Totals, numbers then percentages 1 0 0 3 0 7 2 7 7 29 0 0 14 0 70 % 1.4 .0 .0 4.3 .0 10.0 2.9 --> --> 61.4 .0 .0 20.0 .0100.0 QC = 0 : Fringes not detected. = 1-9 : Fringes detected. The higher number, the better quality. = D : No data in one or more frequency channels. = G : Fringe amp in a freq ch is <.5 times coherent amp only if snr>20. = N : No valid correlator data. = - : Not scanned Base Line: TV Total Obs: 35 Error : 11 % : 31.4 (ERROR: Q-code of either band is less than 4 or letter code, or not scanned) SNR histogram Distribution of X-band SNRs, for each baseline SNR: 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 >> TV: 0 0 0 3 1 1 0 1 1 0 3 1 1 0 0 1 0 15 Total 0 0 0 3 1 1 0 1 1 0 3 1 1 0 0 1 0 15 Total number of obs: 28 Average SNR: 113.7 Distribution of S-band SNRs, for each baseline SNR: 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 >> TV: 0 2 2 0 3 3 2 2 1 2 0 3 2 0 0 0 0 6 Total 0 2 2 0 3 3 2 2 1 2 0 3 2 0 0 0 0 6 Total number of obs: 28 Average SNR: 52.5 -------------------------------- Kentarou Nozawa G. S. I. /Advanced Engineering Services Co., Ltd. aes@gsi.go.jp