INT 208-174 / K08174 Correlation report Tsukuba VLBI Correlator [Geographical Survey Institute, Japan] Observed: Jun 22, 2008 doy174/07:30-174/08:28 Correlated: Jun 24, 2008 Exported: done Station Comments ---------------- TSUKUB32(T-Ts): Low pcal amplitude in S2 causing D code in scan 174/08:06. Manual pcal in fringe fitting. Recorded on K5(VSSP32). WETTZELL(V-Wz): Missed 14 scans (from 174/07:30-174/07:52) due to the observation start was late. Because of problems with automatic observation mode. Recorded on Mark5. See also: The IVS-ops Archives, June 2008 From: RT-20m Wettzell Subject: [IVS-ops] Wettzell has finished K08173 and K08174 Sun Jun 22 05:35:49 EDT 2008 - comment: Intensive eVLBI session with TSUKUB32 and WETTZELL. Recorded Data on Mark5 at WETTZELL were transferred to Tsukuba Correlator via network. Converting Mark5 data into K5 form at Tsukuba Correlator. Processed on K5 correlation system. PF=0.82 Station Clocks -------------- Clocks: GSI Station fmout-gps used rate Comments [usec] [usec] [sec/sec] Ts 0.148 0.148 0.099E-12 Reference Wz -19.372 -20.528 1.795E-12 Date: 2008/06/22 - comment: correlation package:apri_calc(NICT,Ver.2008-02-19). cor(NICT,Ver.2008-02-19). komb(NICT,Ver.2008-02-19). Statistics ---------- PROCESS SUMMARY BY BASELINE/FREQUENCY Base 0 1 2 3 4 5 6 7 8 9 D G N - Tot TV X 0 0 0 0 0 0 0 0 2 19 0 0 2 12 35 TV S 0 0 1 0 0 0 0 0 3 17 0 0 2 12 35 Column Totals, numbers then percentages 0 0 1 0 0 0 0 0 5 36 0 0 4 24 70 % .0 .0 1.4 .0 .0 .0 .0 --> --> 58.6 .0 .0 5.7 34.3100.0 QC = 0 : Fringes not detected. = 1-9 : Fringes detected. The higher number, the better quality. = D : No data in one or more frequency channels. = G : Fringe amp in a freq ch is <.5 times coherent amp only if snr>20. = N : No valid correlator data. = - : Not scanned Base Line: TV Total Obs: 35 Error : 15 % : 42.9 (ERROR: Q-code of either band is less than 4 or letter code, or not scanned) SNR histogram Distribution of X-band SNRs, for each baseline SNR: 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 >> TV: 0 0 0 0 0 1 2 0 0 2 3 0 0 0 0 1 1 11 Total 0 0 0 0 0 1 2 0 0 2 3 0 0 0 0 1 1 11 Total number of obs: 21 Average SNR: 114.7 Distribution of S-band SNRs, for each baseline SNR: 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 >> TV: 0 0 0 0 2 1 0 6 2 0 2 1 0 2 1 1 0 3 Total 0 0 0 0 2 1 0 6 2 0 2 1 0 2 1 1 0 3 Total number of obs: 21 Average SNR: 63.8 --------------------------------- Kentarou Nozawa G. S. I. /Advanced Engineering Services Co., Ltd. aes@gsi.go.jp